Specifications | Dimensions | Manuals
RT Engineering's DIN Series panel meters provide maximum flexibility
in the field of digital indication. The DIN series combines a Universal
input scheme with a product so Versatile, it can be used in a wide
variety of applications - one model that's capable of doing many things
well.
Voltage Input Models accept AC or DC inputs from 50 MV to 500 V
from a multitude of signal sources. The DIN Series meters can monitor
and display electrical units, such as AC or DC amps and volts, or
other engineering units, such as FPM, RPM, GPM and others.
Accuracy, Reliability, and Versatility backed by a two-year warranty.
Typical Input Signals:
|
AC or DC signals from motor armatures,
line or reference voltages, tachometers, force transducers
(load cells), shunts, current transformers, pressure and flow
transducers
|
Input Ranges:
|
(A) 50mvDC; 100mvAC (B) 500mvDC; 1VAC
(C) 5VDC; 10VAC (D) 50VDC; 100VAC.
|
Note:
|
"D" scale accepts voltages
up to 500VDC/480VDC
|
Maximum Input and Overrange:
|
1000% of range or 500V AC and DC which
ever is less
|
Input Resistance at Nominal Scale
Values:
|
20K Ohms/volt, AC and DC
|
AC Frequency Range:
|
Max. signal: 500 Hz, Min. signal: 40
Hz
|
Accuracy:
|
.5% linear +/- 1 digit full scale
|
Sampling Time:
|
.4 seconds/reading update
|
Response Time
(0 to full scale):
|
5 seconds
|
Power Requirement:
|
115VAC (+/- 10V), 50/60 Hz, 2 watts
|
Operating Temperature:
|
5°C to 50 °C
|
Calibration Method:
|
Scale selecting jumper and a 20-turn
potentiometer for coarse adjustment and a multi-turn potentiometer
for fine tuning
|
Construction:
|
RFI shielded high impact (UL94V-0) plastic case with LOX-IT self locking Lexan bezel over display
|
Weight:
|
1 pound
|
Typical Input Signals:
|
Current source, typically 4-20MA, 5-50MA,
or offset voltage 1-5VDC, etc.
|
"BIAS" Adjustment Range:
|
0-40% of full scale
|
"SCALE" Adjustment Range:
|
10-100% of full scale
|
Shunt Resistance:
|
Infinite or 250 ohms customer jumper
selectable (other values of 50 to 600 ohms inclusive are available
on customer request)
|
Accuracy:
|
.5% linear +/- 1 digit full scale
|
Sampling Time:
|
.4 seconds/reading update
|
Response Time (0 to full scale):
|
5 seconds
|
Power Requirement:
|
115VAC (+/- 10V), 50/60 Hz, 2 watts
|
Operating Temperature:
|
5°C to 50°C
|
Construction:
|
RFI shielded high impact (UL94V-0) plastic
case with LOX-IT self locking Lexan bezel over display
|
Weight:
|
1 pound
|
Typical Input Signals:
|
Standard magnetic pickup (30 inches per
sec. minimum gear or sprocket speed at 1/64" maximum
gap) Hall effect type pickup which can operate from the 5VDC
meter supply or slow speed type pickup such as RT Engineering
P/N RT-58426. A 1/32" maximum gap is required between
the gear and pickup. Output wave-form from either six step,
pulse width modulated (PWM), or current source inverter up
to 480VAC when the meter has proper interface. Signal isolation
transformer P/N RT-TA-181210 is available if customer required.
|
Standard Input Signal Range:
|
5PPS to 22,000PPS
|
Accuracy:
|
.5% linear +/- 1 digit full scale
|
Sample Time:
|
.4 seconds/reading update
|
Response Time (0 to full scale):
|
5 seconds
|
Power Requirement:
|
115VAC (+/- 10V), 50/60 Hz, 2 watts
|
Operating Temperature:
|
5°C to 50°C
|
Calibration Method:
|
Scale selecting jumper and a 20-turn
potentiometer for coarse adjustment and a multi-turn potentiometer
for fine tuning
|
Construction:
|
RFI shielded high impact (UL94V-0) plastic
case with LOX-IT self locking Lexan bezel over display
|
Weight:
|
1 pound
|
Click for a larger view.
DIN35 & DIN45 | DIN35P & DIN45P | DIN35BP & DIN45BP | DIN35B & DIN45B
|